The presentation of the installation must take into account the principle of established operational and the technological limits.

Installation requirements
Environmental requirements
The implementation of this installation depends primarily on the adjustment of the Polhemus sensors. These sensors are very sensitive to all the metal elements in the vicinity.  It is imperative that the placement of the installation remain out of reach of any elements of this nature. The part which houses the whole has the following dimensions:
4m X 4m for the displacement of the participant
a release of 2m on each sides for the public
Fixing of the Polhemus antenna to 2,50 in height
 
Technical needs
In addition to the specific needs of the data-processing, the area accommodating the installation must provide:
2 monitors PAL or NTSC
1 technical room
Several electrical connectors
Network access
The CICV provide
Image Hardware  :
Station Silicon O2, video card,  processor R5000, 300 Mg Ram + Screen RVB data processing
Camera Hi8 pal
Sound_Hardware:
Machintosh Performa 5400_/180 32 Mg Ram
Synthesizer Midi Roland SoundCanvas SC-55mkII
Tracking Hardware:
Polhemus Fastrak box
Antenna Long Ranger
4 sensors
Participant equipment:
Raincoat
Visualization helmet Virtual Research VR4 image and sound
Reception facilities provided
Other possible Imaging Hardware (more powerfull must be find by the stucture who is presenting Icare)
Harware image:
Station Silicon Onyx2 Infinite Reality, entry video card DIVO, out card video DG5-8, 2 processors R10000, 64 Mg Texture Ram , 200 Mg Ram + Screen  RVB data processing
Conversion card : analog digital or digital camera
Installation
The set-up of the installation requires one full day with one people.
Presentation
During the presentation, a person from the structure presenting Icare helps the participant discover the environment.
Disassembling
A half day of disassembling..
Human Resources
The presentation of the installation requires the presence of one people. The reception facilities will deal with the expenses of lodging and food of this one people.
Cost
The hiring of this installation is established at :
  6 000 F including all taxes Fixed price for the assembly and disassembling..
  4 000 F including all taxes Per day of presentation
15 000 including all taxes For one full week